  Specifications  
             
 
These values represent the damage threshold of the module. Stress in excess of any of the individual Absolute Maximum Ratings can cause immediate catastrophic damage to the module even if all other parameters are within Recommended Operating Conditions.
Absolute maximum rating
Parameters Symbol Min. Typical Max. Unit
Power Supply Voltage VCC 0.5 +3.8 V
Storage Temperature Tst -40 +85 °C
Operating Case Temperature Tc -5 +70 °C
Relative Humidity RH 5 95 %
RX Input Average Power Pmax - 0 dBm
 
Recommended  Operating  Environment  specifies  parameters  for  which  the  electrical  and  optical characteristics hold unless otherwise noted.
Recommended operating environment
Parameter Symbol Min. Typical Max Unit
Power Supply Voltage VCC 3,135 3.300 3,465 V
Power Supply Current ICC - 420 610 mA
Module Power Dissipation Pm - 1.4 2 W
Operating Case Temperature TC -5 25 70 °C
 
The following optical characteristics are defined over the Recommended Operating Environment unless otherwise specified.
Optical characteristics
Parameter Symbol Min. Typical Max Unit
Transmitter
Center Wavelength λt 1530 - 1565 nm
Spectral Width (-20dB) Δλ20 - - 0.3 nm
Side Mode Suppression Ratio (min) SMSR - 30 - dB
Average Optical Power Pavg 0 - +4 dBm
Extinction Ratio ER 9 - - dB
Relative Intensity Noise RIN - - 128 dB/Hz
Optical Return Loss Tolerance Orl - - 21 dB
Receiver
Input Operating Wavelength λr 1260 - 1620 nm
Receiver Sensitivity (9.95~10.7) Psens1 - - -24 dBm
Receiver Sensitivity (80km, 9.95~10.7) Psens2 - - -22 dBm
Maximum input power RX-overload -7 - - dBm
Loss of signal asserted Lsa -34 - - dBm
Loss De-Asserted Lda - - -24 dBm
LOS Hysteresis Lh 0.5 - - dB
 
The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.
Electrical characteristics
Parameter Symbol Min. Typical Max Unit
Data Rate Mra 0.6 10,3 11.3 Gbps
Power Consumption - 1000 1200 mW
Transmitter
Input differential impedance Rim - 100 - Ω
Differential data input VtxDIFF 120 - 850 mV
Transmit disable voltage VD 2.0 - Vcc3+0.3 V
Transmit enable voltage Ven 0 - 0.8 V
Transmit disable assert time Vn - - 100 V
Receiver
Differential output swing Vout P-P 350 - 850 mV
Rise/Fall time Tr / Tf 24 - - ps
Loss of signal asserted VOH 2 - Vcc3+0.3 V
Loss of signal negated VOL 0 - 0.4 V
 
Pin definition
Pin Symbol Name/Description
1 VEET Transmitter Ground
2 Tx_FAULT Transmitter Fault
3 Tx_DIS Transmitter Disable. Laser output disabled on high or open
4 SDA 2-wire Serial Interface Data Line
5 SCL 2-wire Serial Interface Clock Line
6 MOD_ABS Module Absent. Grounded within the module
7 RS0 Rate Select 0
8 RX_LOS Loss of Signal indication. Logic 0 indicates normal operation
9 RS1 Rate Select 1
10 VEER Receiver Ground
11 VEER Receiver Ground
12 RD- Receiver Inverted DATA out. AC Coupled
13 RD+ Receiver DATA out. AC Coupled
14 VEER Receiver Ground
15 VCCR Receiver Power Supply
16 VCCT Transmitter Power Supply
17 VEET Transmitter Ground
18 TD+ Transmitter DATA in. AC Coupled
19 TD- Transmitter Inverted DATA in. AC Coupled
20 VEET Transmitter Ground